Skip to content
HOME  /  PRODUCTS  /  HEAT EXCHANGER TUBING
STAINLESS STEEL SEAMLESS TUBES

Heat Exchanger Tubing

Small to medium-diameter, high-precision tube used as the primary heat transfer element in shell-and-tube exchangers, condensers, reboilers and other process bundles.

TUBE OD 6.35 - 50.80 mm WALL 0.5 – 8.0 MM UP TO 12 M
OVERVIEW

The heat transfer element, and the failure point if it is wrong

Heat exchanger tubing is typically cold process seamless, with tight dimensional tolerances, a smooth internal bore and the corrosion and temperature resistance needed to withstand cyclic thermal stress and aggressive process fluids.

Tubes are usually supplied bright annealed or pickled and passivated for easy cleaning and low fouling. Common industrial sizes are OD 19 mm x 2 mm, 25 mm x 2.5 mm and 38 mm x 2.5 mm, with most process exchangers falling between 10 and 50.8 mm OD.

Tube is supplied up to 12 metres to cover most shell-and-tube bundles.

Shell-and-tube heat exchanger stainless steel tube bundle
SPECIFICATION
OD RANGE
Tube OD 6.35 – 50.80 mm; most process exchangers 10 – 50.8 mm
WALL THICKNESS
0.5 – 8.0 mm depending on pressure and thermal duty
COMMON SIZES
OD 19 x 2 mm, OD 25 x 2.5 mm, OD 38 x 2.5 mm
LENGTHS
Up to 12 m
GRADES
304 / 304L, 316 / 316L; 904L, super austenitic and duplex 2205 for severe duties
STANDARDS
ASTM A213 / SA213, A268, A789, A1016
FINISH
Bright annealed, pickled and passivated, or mechanically polished
TESTING
Hydrostatic or pneumatic pressure test; eddy current or ultrasonic inspection; dimensional and visual checks per MTC
CHARACTERISTICS

Engineered for thermal duty

01

Uniform wall

Cold finished process gives even wall, roundness and pressure integrity.

02

Low fouling

BA or pickled-passivated bore resists deposition and cleans more readily in service.

03

Thermal cycling

Grade and wall selection matched to cyclic stress and process chemistry.

04

Full inspection

Pressure test, NDT and dimensional checks recorded against EN 10204 3.1 / 3.2.

QUICK REFERENCE — TYPICAL EXCHANGER TUBES
OD (mm) Typical wall Typical use
10 – 12.70.8 – 1.5 mmLow-pressure preheaters, small exchangers
15 – 191.00 - 2.00 mmGeneral process exchangers
25 - 321.6 - 2.5 mmCommon process and condenser tubes
32 – 382.00 - 4.00 mmHigher-pressure or large-duty exchangers
50 – 101.62.00 - 5.00 mmLarge-duty or high-pressure bundles
APPLICATIONS

Where exchanger tubing is used

Shell-and-tube heat exchangers in refineries, chemical plants, power plants and LNG terminals
Condensers and reboilers where cleanability and corrosion resistance are critical
Steam and process fluid preheaters and coolers, including offshore and marine systems
Seawater coolers and high-chloride service in duplex and super austenitic grades
ORDERING

What to send us for a firm quote

The more of this we have up front, the faster the quotation and the fewer clarifications later. Partial enquiries are welcome — we will tell you what else the specification needs.

Send an enquiry
Grade
e.g. 304L, 316L, 321, 904L, duplex 2205
OD and wall
Outside diameter x wall thickness in mm or inch
Length or form
Straight length, U-bend leg and radius, or coil length
Standard
ASTM / ASME, EN or DIN specification to be certified against
Finish
Mill, pickled, BA, mechanically polished or electropolished with target Ra
Testing
Hydrostatic or pneumatic, eddy current, ultrasonic, boroscope
Documentation
EN 10204 3.1 or 3.2, surface analysis, heat-code marking
Quantity and packing
Tonnage or metres, plus packing and marking requirements
FREQUENTLY ASKED

Heat Exchanger Tubing — common questions

Which sizes are most commonly ordered?

OD 19 x 2 mm, 25 x 2.5 mm and 38 x 2.5 mm cover most process duties. The majority of process exchangers fall between 10 and 50.8 mm OD.

What finish is best for fouling resistance?

Bright annealed or pickled and passivated bores resist deposition and clean more readily than a mill finish.

Can you supply non-standard lengths?

Tube is supplied up to 12 m to suit shell-and-tube bundle designs.

Which grades suit seawater cooling?

904L, super austenitic and duplex 2205 are specified for highly corrosive or high-chloride environments such as seawater coolers and offshore service.

Enquire about Heat Exchanger Tubing

Send grade, OD, wall, length, standard and finish for a firm quotation.

Request a Quote